    380V 3PH 50HZ Precision Air Conditioning System Row Level Air Cooled CRA3050

    Ask Lasest Price
    Brand Name : LIRUISI
    Model Number : CRA3050
    Price : negotiation
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 9999 units
    Delivery Time : 8 working days
    • Product Details
    • Company Profile

    380V 3PH 50HZ Precision Air Conditioning System Row Level Air Cooled CRA3050

    LIRUISI Row-Level Air-Cooled Machine Room Precision Air Conditioner CRA3050

    Product introduction:

    LRS-CRA series row-level air-cooled room air conditioner is a temperature control product specially designed for medium and high heat density data centers, which is installed close to the heat source, shortens the cold air flow path, and accurately processes the sensible heat generated by the server, which is an ideal choice for green energy-saving data centers and various electronic equipment rooms.Application scenarios: small and medium-sized data centers, modular data centers, cabinet cooling (hot) channel transformation, medium and high heat density communication equipment and computer rooms, etc.


    LIRUISI room-level air-cooled precision air conditioning CRA3050 is an air conditioning system that controls the temperature, humidity, and air flow rate of the data center through compression refrigeration.


    Its working principle is as follows:

    1. Refrigeration cycle: The refrigeration cycle is achieved by evaporating and condensing the refrigerant to absorb and release heat, in order to lower the temperature of the data center. Specifically, indoor air is drawn into the air conditioning system, treated through filters and humidifiers, and then enters the evaporator, where it exchanges heat with the refrigerant. At the same time, the moisture in the air is absorbed, reducing the air temperature and relative humidity. After evaporation, the refrigerant is compressed and enters the condenser, where it exchanges heat with outdoor air (or cooling water), releasing heat and returning the refrigerant to its liquid state.

    2. Control system: The control system detects the state of the data center, including temperature, humidity, and air flow rate, through sensors. These signals are transmitted to the controller, which then controls the system based on set values. By precisely adjusting the speed of the compressor, fan, and valve opening and closing, stable control of the data center temperature, humidity, and air flow rate can be achieved.

    3. Heat dissipation system: The heat dissipation system mainly uses pipes, radiators, and fans to discharge the heat from the evaporator and condenser. Specifically, the condenser releases heat through cooling water or air, while the evaporator releases heat by discharging outdoor air or a drainage pipe.


    Product parameters:

    LIRUISI【CRA series row-level air-cooled room air conditioner】CRA series row-level air-cooled room air conditioning and refrigeration system [size and weight of internal unit]
    Indoor unit modelCRA3050Unit width (mm)600
    Main power supply380V3PH~50HZUnit depth (mm)1200
    Air supply methodFront air supplyUnit height (mm)2000/2200
    CRA series row-level air-cooled computer room air conditioner [performance parameters]Weight (kg)310
    Cooling capacity (kW)50CRA series row-level air-cooled room air conditioning and refrigeration system [performance parameters of external unit] [40°C]
    apparent cooling capacity50Flat panel outdoor unit modelLRS-CMT077SP
    Maximum working current of the unit A54Compact outdoor unit modelLRS-CMT077SF
    Number of compressors1CRA series row-level air-cooled room air conditioning and refrigeration system [performance parameters of external unit] [45°C]
    Fan formEC centrifugal fanFlat panel outdoor unit modelLRS-CMT088SP
    Number of fans3Compact outdoor unit modelLRS-CMT088SF
    Circulating air volume (m3/h)10800Centralized outdoor unit modelLRS-CMT088SF
    Heating capacity (kw)9CRA series row-level air-cooled room air conditioning block refrigeration system [Recommended power distribution specifications]
    Humidification capacity (kg/h)4.5Recommended open63
    CRA series row-level air-cooled room air conditioning and refrigeration system【Connection pipe size specifications】Indoor unit power cord (mm2)4*16+1*16
    Liquid tube (mm)15.88
    Trachea (mm)22
    Humidification inlet pipe (external thread)G3/4
    Unit water pump drain pipe (mm)ID9.53*OD17.02
    Unit natural drain pipe (mm)ID16*OD24